Print-related Product

Dampening Solution Circulator and Ink Unit Temperature Control in One Unit

Space-saving in a factory, and reduction of exhaust heat apparatus

It is highly efficient equipment with the feeling of unification which dedicated various functions to one cabinet.

SPACE PAIR(ECO)

SPACE PAIR

Features

  • It is the combination unit which unified the dampening solution recirculation system and ink unit temperature control system.
  • Reduced installation space (Compared with the conventional machine, reduced about 60%)
  • Package control by a color liquid crystal touch screen
  • Cooling of dampening solution is a water cooling refrigerator without exhaust heat into a factory.
  • Inverter chiller allows significant energy savings
  • Alcohol control and etch solution control are standard specification.
  • Integrated communication control as an option
Catalog Download Inquiry Form

Specifications

Model (Including a Chilling Unit)

SPACE PAIR (ECO) □□□*-1SR1/2SR1/2SR2/4SR1/4SR2

* Cooling Capacity
VI (250) ・・・ 25.0KW
VII (375) ・・・ 37.5KW
VIII (500) ・・・ 50.0KW
IX (630) ・・・ 63.0KW

Model 1SR1 2SR1 2SR2 4SR1 4SR2
Power Supply 3-Phase 200V
Tank Capacity (Ink Unit Temperature Control System) 130L (Fixed Quantity) 188L (Fixed Quantity)
Tank Capacity (Dampening Solution Recirculation System) 150L (Fixed Quantity)
No. of Temperature Control 1 2 4
Temperature Control Heating/ Cooling Control
Touch Screen 7 Inch Color Liquid Crystal Touch Screen
Error Display Error Indication and Buzzer
Dimensions (W×D×H) 2150×800×1976 (mm) 2550×800×1976 (mm)
Etch Control Change-over of Etch Density Control Mode and pH Monitoring Mode
IPA Control IPA Control Device [alcon]

SPACE PAIR(ECO) UV

SPACE PAIR H-UV

Features

  • It is a combination unit which unified UV cooling function in addition to the function of SPACE PAIR (ECO).
  • Main unit installation spaces are reduced by about 60% (conventional model ratio of our company).
  • The power-saving effect by adoption of an inverter chiller (Compared with the conventional machine, reduced about 16%)
  • The addition of UV cooling function is also made to serve a double purpose by one set of an external chilling unit.
  • Reduction of an exterior unit installation space and piping is possible.
Catalog Download Inquiry Form

Specifications

Model (Including a Chilling Unit)

SPACE PAIR(ECO) UV □□□*-2SR1/3SR1/5SR1/3SR2/5SR2

* Cooling Capacity
250 ・・・ 25.0KW
375 ・・・ 37.5KW
500 ・・・ 50.0KW
630 ・・・ 63.0KW

Model 2SR1 3SR1 5SR1 3SR2 5SR2
Power Supply 3-Phase 200V
Tank Capacity (Ink Unit Temperature Control System) 130L (Fixed Quantity) 188L (Fixed Quantity) 130L (Fixed Quantity) 188L (Fixed Quantity)
Tank Capacity (Dampening Solution Recirculation System) 150L (Fixed Quantity)
No. of Temperature Control (Ink Unit Temperature Control) 1 2 4 2 4
No. of Temperature Control (H-UV Temperature Control) 1 1 1 1 1
Temperature Control Heating/ Cooling Control (UV is only in cooling control.)
Touch Screen 5.7 Inch Color Liquid Crystal Touch Screen
Error Display Error Indication and Buzzer
Integrated Communication Control Function External (PQC) Communication Function
Dimensions (W×D×H) 2750×800×1976 3150×800×1976 2750×800×1976 3150×800×1976
Etch Control Change-over of Etch Density Control Mode and pH Monitoring Mode
IPA Control IPA Control Device [alcon]

PeDeS

PeDeS

 

 

Catalog Download Inquiry Form

Features

  • PeDeS is an ultimate multirole unit combined dampening solution recirculation system, ink unit temperature control system, dampening solution filtration system, dust collector and blower cabinet chiller in one unit.
  • Inverter chiller and closed cooling water circuit ensures steady cooling water temperature control (Function of ink unit temperature control and blower cabinet temperature control)
  • Digital scroll compressor ensures steady dampening solution temperature control (Function of dampening solution recirculation)
  • Function of dampening solution filtration system comes equipped with high quality filters and it enables high efficiency of filtration and long life of dampening solution.
  • Embedded function of dust collector with cyclonic system and explosion-proof structure prevents decreasing suction power caused by clogged filters and ensures safety against dust explosion.
  • Significant energy saving effect with an inverter chiller and a digital scroll compressor.
  • Closed cooling water circuit is adopted for piping and it helps to reduce red rust and prolongs the cooling water life.
  • Function of dampening solution filtration system reduces requirement for exchange of dampening solution and amount of waste dampening solution.
  • Heat exchange by a water-cooled condenser doesn’t influence to intake/ outtake air in a factory.
  • It consists of three units of “ink unit/ blower cabinet cooling unit”, “dampening solution circulation/ dampening solution filtration unit”, and a “dust collector unit”, and an installation arrangement is possible according to the layout of a factory.

Specifications

Model (Including a Chilling Unit)

PeDeS *1□□□*2- 2SR1/4SR1/2SR2/4SR2/2SR3/4SR3

*1
1 ・・・ Blower Cabinet Cooling (Without)
2 ・・・ Blower Cabinet Cooling (With)

*2 Cooling Capacity
IV (125) ・・・ 12.5KW
V (190) ・・・ 19.0KW
VI (250) ・・・ 25.0KW
VII (375) ・・・ 37.5KW
VIII (500) ・・・ 50.0KW
IX (630) ・・・ 63.0KW
X (750) ・・・ 75.0KW

Model 2SR1 4SR1 2SR2 4SR2 2SR3 4SR3
[Ink Unit Temperature Control Part]
No. of Temperature Control (Ink Unit Temperature Control Part) 2 4 2 4 2 4
Temperature Control Heating/ Cooling Control (Water Cooling with Solenoid Valve)
Cooling Water Circuit Method Closed Cooling Water Circuit
Cooling Tank Outdoor Pressure Tank (Embedded Expansion Tank and Water Circulation Pump)
[Dampening Solution Recirculation Part]
Tank Capacity (Dampening Solution Recirculation System) 150L (Fixed Quantity)
No. of Water Circulation Pump 1 2
Cooling Capacity (50/ 60Hz) 6.1/7.3KW 12.7/13.8KW 15.9/18.7KW
Etch Control Change-over of Etch Density Control Mode and pH Monitoring Mode
IPA Control IPA Control Device [alcon]
[Dampening Solution Filtration Part]
Filtration Capacity 36~65L/ min
Housing Housing A (5 pcs x Filter Cartridge) + Housing B (5 pcs x Filter Cartridge)
Filter Cartridge Standard Combination ・・・ 5 pcs x Filter-A (Filtration 3µm) + 2 pcs x Filter-B (Filtration 3µm) + 3 pcs x Filter-C (Special Adsorption Material)
[Dust Collection Part]
Power Supply 3-Phase 200V (Separate Power Supply)
Operation Control Controlled by Switch or External Signal of AC200V
Motor Main Unit 2.2kW/ Blower Fan 0.2kW
Dust Collection Cyclon
Anti-explosion Explosion-proof Mechanism
[Blower Cabinet Temperature Control Part] Only PeDeS 2
Temperature Control Water Cooling with Solenoid Valve
Heat Exchanger Condenser-A/ Condenser-B (The number of use changes with cabinet calorific value.)
Fan for Heat Exchanger Condenser-A (2 Fans per 1 Condenser)/ Condenser-B (1 Fan per 1 Condenser)
Cooling Water Circuit Method Closed Cooling Water Circuit
No. of Temperature Control 1
[Common]
Power Supply 3-Phase 200V
Touch Screen 7 Inch Color Liquid Crystal Touch Screen
Error Display Error Indication and Buzzer