SPACE PAIR(ECO) UV

Features
- It is a combination unit which unified UV cooling function in addition to the function of SPACE PAIR (ECO).
- Main unit installation spaces are reduced by about 60% (conventional model ratio of our company).
- The power-saving effect by adoption of an inverter chiller (Compared with the conventional machine, reduced about 16%)
- The addition of UV cooling function is also made to serve a double purpose by one set of an external chilling unit.
- Reduction of an exterior unit installation space and piping is possible.
Specifications
Model (Including a Chilling Unit)
SPACE PAIR(ECO) UV □□□*-2SR1/3SR1/5SR1/3SR2/5SR2
* Cooling Capacity
250 ・・・ 25.0KW
375 ・・・ 37.5KW
500 ・・・ 50.0KW
630 ・・・ 63.0KW
Model | 2SR1 | 3SR1 | 5SR1 | 3SR2 | 5SR2 |
---|---|---|---|---|---|
Power Supply | 3-Phase 200V | ||||
Tank Capacity (Ink Unit Temperature Control System) | 130L (Fixed Quantity) | 188L (Fixed Quantity) | 130L (Fixed Quantity) | 188L (Fixed Quantity) | |
Tank Capacity (Dampening Solution Recirculation System) | 150L (Fixed Quantity) | ||||
No. of Temperature Control (Ink Unit Temperature Control) | 1 | 2 | 4 | 2 | 4 |
No. of Temperature Control (H-UV Temperature Control) | 1 | 1 | 1 | 1 | 1 |
Temperature Control | Heating/ Cooling Control (UV is only in cooling control.) | ||||
Touch Screen | 5.7 Inch Color Liquid Crystal Touch Screen | ||||
Error Display | Error Indication and Buzzer | ||||
Integrated Communication Control Function | External (PQC) Communication Function | ||||
Dimensions (W×D×H) | 2750×800×1976 | 3150×800×1976 | 2750×800×1976 | 3150×800×1976 | |
Etch Control | Change-over of Etch Density Control Mode and pH Monitoring Mode | ||||
IPA Control | IPA Control Device [alcon] |