Dampening Solution Recirculation Systems

The printing method of offset printing uses rebounding of ink and water, and the water used is called dampening solution. Thermal management and ingredient management are very important for this dampening solution, and it also affects printing quality. A dampening solution recirculation system is the equipment which keeps ingredient and temperature of dampening solution constant in order to perform high-quality printing, and circulates dampening solution to a printing press.

TOP-ONE ECO series is the product which collected experience and technology of COSMOTECH. It is equipment of the energy-saving type which has standard adoption of the refrigerant gas of R407C.

TOP-ONE ECO 402

TOP-ONE ECO 402

TOP-ONE ECO 402Customer-delighting functions were added to simplicity and compactness of TOP-ONE ECO 402s.

TOP-ONE ECO 402 has automatic injection of etch and IPA.

Operation status can be recognized quickly on the touch screen and it is also convenient for settings.

Catalog Download Inquiry Form

Features

  • Stable cooling ability by adopting low vibration chiller.
  • Simple and easily viewable operation portion.
  • Equipped filter bags which minimize foaming and rid impurities effectively.
  • Adopt eco-friendly refrigerant (R407C)
  • Cleaning/ maintenance of the reservoir is every easy.
  • Compact design to minimize installation space.
  • Automatic injection of etch and IPA
  • Touch screen operation

Specifications

Name TOP-ONE ECO 402
Power Supply 3-Phase 200V Input Breaker 20A
Current/ Capacity Approx. 12A/ 4.2kVA
Refrigerator Air Cooling Type 1.62kW
Refrigerant R407C
Circulation Pump 3-Phase 200V 370W
Water Supply Automatic Water Supply
IPA Control alcon
Dimensions W600×D750×H1200 (mm)
Adaptable Presses 6 Colors 26/29″ / 6 Colors 32″ / 2 Colors or Less 40″

TOP-ONE ECO 502 / 502W

TOP-ONE ECO 502(W … Water Cooling Type)

TOP-ONE ECO 502 is well-equipped and reliable unit for 40″ and 44″ presses.

Automatic etch/ IPA injection, touch screen operation and such “must” functions are equipped.

Dampening solution concentration is controlled by either the etch density control mode or the pH monitoring mode.

There are no screws on the cover plates and it makes cleaning and maintenance easier.

Moreover, if a water cooled type refrigerator is adopted, amount of exhaust heat in a factory can be cut. (In the case of a water cooled type refrigerator, it usually becomes combined use with a roller cooling system. A roller cooling system and a chilling unit are sold separately.)

Catalog Download Inquiry Form

Features

  • The added amount of etch solution is controlled by either the etch density control mode or the pH monitoring mode.
  • Since there is no screw on the side covers, they can be easily removed.
  • The liquid crystal display shows the operation status clearly.
  • The touch screen makes operation easier.

Specifications

Name TOP-ONE ECO 502 / 502W
Power Supply 3-Phase 200V Input Breaker 30A
Current/ Capacity Approx. 13A/ 4.5kVA
Refrigerator Air Cooling Type/ Water Cooling Type 1.99kW
Refrigerant R407C
Circulation Pump 3-Phase 200V 180/ 250W
Etch Solution Control Change-over of etch density control mode and the pH monitoring mode
IPA Control Water Surface Detection
Dimensions W800×D750×H1470 (mm)
Adaptable Presses 4~6 Colors 40″ / 4 Colors or Less 32″

TOP-ONE ECO 602 / 602W

TOP-ONE ECO 602W(W … Water Cooling Type)

TOP-ONE ECO 602 is a unit for large format and web presses.

It inherited the basic design pattern and functions from “ECO” series. In addition, considering customer’s usability, the top panel is designed to slide open.

Moreover, if a water cooled type refrigerator is adopted, amount of exhaust heat in a factory can be cut. (In the case of a water cooled type refrigerator, it usually becomes combined use with a roller cooling system. A roller cooling system and a chilling unit are sold separately.)

Catalog Download Inquiry Form

Features

  • The added amount of etch solution is controlled by either the etch density control mode or the pH monitoring mode.
  • Top panel is designed to slide open.
  • The liquid crystal display shows the operation status clearly.
  • The touch screen makes operation easier.

Specifications

Name TOP-ONE ECO 602/ 602W
Power Supply 3-Phase 200V Input Breaker 50A
Current/ Capacity Approx. 22A/ 7.6kVA
Refrigerator Air Cooling Type/ Water Cooling Type 3.54kW
Refrigerant R407C
Circulation Pump 3-Phase 200V 450 W×2
Etch Solution Control Change-over of etch density control mode and the pH monitoring mode
IPA Control Water Surface Detection
Dimensions W1200×D1000×H1570 (mm)
Adaptable Presses 7~8 Colors 40″ / 5~8 Colors 32″ / 5 Colors or Less 50″ / Web Press